Photos don’t exaggerate. The difference between a leaking, under-insulated attic and a sealed, properly insulated envelope shows up in thermal imaging, blower-door numbers, and monthly energy bills. Below are recent jobs we’ve completed in Tustin and nearby neighborhoods. Each one includes the before-and-after blower-door reading, the materials used, and what the homeowner received when we left.

Call (657) 286-7673

Recent Transformations

Attic Air Sealing + Blown-In Fiberglass, Tustin Ranch

Attic floor before air sealing showing gaps around top plates and recessed light housings, and after sealing with blown-in fiberglass insulation installed to R-38
Attic air sealing and blown-in fiberglass upgrade, Tustin Ranch - Owens Corning ProPink LooseFill to R-38 over sealed envelope.

The homeowner in Tustin Ranch had original 1980s insulation, compressed to about R-11 with gaps around every top plate and can light. We pulled it back, sealed all penetrations with fire-rated caulk and foam, replaced the can lights with airtight IC-rated housings, then blew in Owens Corning ProPink to a true R-38. Blower-door test read 3,800 CFM50 before sealing and 2,100 after. The written scope, warranty, and photo record were delivered before we started; the after photos and final blower-door number were in their inbox by 6 PM the same day.

Crawl Space Encapsulation & Vapor Barrier, Old Town Tustin

Dirt crawl space with standing water and mold-stained joists before encapsulation, and after with white vapor barrier, sealed piers, and dehumidifier
Crawl space encapsulation, Old Town Tustin - 12-mil reinforced vapor barrier, sealed piers, conditioned with dehumidifier.

This 1952 pier-and-beam in Old Town Tustin had a dirt floor, standing water after rain, and fiberglass batts hanging wet from the joists. We removed the saturated insulation, remediated the mold-affected areas, laid a 12-mil reinforced vapor barrier with sealed seams at all piers and walls, and installed a dedicated dehumidifier set to 55% relative humidity. The wood moisture content dropped from 22% to 11% in ten days. Under Haven Standard Clause 1, the written price covered everything including the dehumidifier electrical circuit; no change orders, no surprises.

Spray Foam Insulation, New Construction Addition, North Tustin

Open stud walls and roof deck before spray foam application, and after with Icynene open-cell foam filling cavities completely
Open-cell spray foam, North Tustin addition - Icynene Classic Max, 3.5 inches in walls, 5.5 inches in roof deck for conditioned attic.

A North Tustin homeowner was mid-build on a 420-square-foot master suite addition and wanted a conditioned attic with no ducts in unconditioned space. We sprayed Icynene Classic Max open-cell foam - 3.5 inches in the walls for R-13, 5.5 inches in the roof deck for R-21 and an airtight seal. The general contractor’s rough blower-door target was 3.0 ACH50 for the whole house; the addition alone tested at 1.8 ACH50 before tie-in. We provided the builder with dated photos of every lift thickness, the batch numbers, and the final blower-door report for their own documentation.

Insulation Removal & Replacement After Rodent Damage, Lemon Heights Area

Contaminated fiberglass insulation with rodent droppings and tunnels before removal, and after with sanitized attic floor and new GreenFiber blown-in cellulose
Insulation removal, sanitization, and replacement with GreenFiber cellulose, Lemon Heights - R-38 after full decontamination and air sealing.

The attic in this Lemon Heights home had been a roof rat highway for two seasons. The fiberglass was tunneled through, compressed with droppings, and useless below R-8 in most areas. We HEPA-vacuumed everything out, sanitized the deck and joists, sealed every gap over 1/4 inch with rodent-proof mesh and foam, then blew in GreenFiber cellulose to R-38. The thermal scan showed a 14-degree surface temperature difference between the old contaminated attic and the new one. We also installed a one-way exit tunnel at the gable vent the rats were using, sealed it two weeks later, and documented both visits in the photo record.

Radiant Barrier + Attic Air Sealing, Cowan Heights

Unshaded dark roof deck radiating heat into attic before radiant barrier, and after with perforated foil stapled to rafters and sealed attic floor below
Radiant barrier and attic air sealing, Cowan Heights - perforated foil on rafters, sealed envelope below, R-38 blown fiberglass.

This Cowan Heights home had a south-facing composite shingle roof with no shade. Attic temperatures hit 145°F in August, and the second-floor AC ran until 11 PM most nights. We air-sealed the attic floor to 2,400 CFM50, blew Owens Corning fiberglass to R-38, then stapled perforated radiant barrier foil to the rafter bottoms. The attic peaked at 108°F the following August afternoon - a 37-degree drop. The homeowner’s August SCE bill dropped 23% year-over-year. We published the before-and-after blower-door numbers, the thermal imaging, and the utility comparison in their job folder.

Wall Insulation Retrofit, Tustin Legacy Area

Exterior wall with siding removed showing empty stud cavity before, and after with dense-packed cellulose filling cavity completely
Dense-pack cellulose wall insulation, Tustin Legacy - GreenFiber dry-packed to 3.5 lb/cu ft through exterior siding removal and replacement.

A Tustin Legacy homeowner was re-siding anyway and asked us to fill the empty 2×4 walls while the Hardie panels were off. We dense-packed GreenFiber cellulose at 3.5 pounds per cubic foot through each stud bay, achieving R-13 and eliminating the convection loops that had made the west-facing rooms unbearable by 4 PM. The siding crew replaced the panels the next morning. We tested one wall cavity with a borescope before and after - empty, then packed tight to the top plate. The written scope specified the density target, the material, and the borescope verification; the photo record showed every bay number and its fill.

Want Results Like These?

Professional installer cutting pink fiberglass batt insulation in an attic
Want Results Like These?

Every job starts with a written price, a written scope, and a written warranty before anyone lifts a tool. That’s Haven Standard Clause 1, and it’s how we’ve worked since 2016. Call (657) 286-7673 to schedule a free assessment in Tustin. We’ll measure what you have, show you what’s leaking, and give you a flat price you can compare. Bring us any competing written estimate - we’ll read it with you, line by line, at no charge.

Written by Wes Okafor, Owner at Topside Attic Insulation Tustin, serving Tustin since 2016.

Need Insulation help in Tustin? Licensed & insured · 1-hour response · free estimates
Call (657) 286-7673
Local Service Coverage

Request a Free Estimate in Tustin

Tell us what you need - Topside Attic Insulation Tustin responds fast. No obligation.

By reaching out through this form, you agree to our Privacy Policy and consent to receive communications by telephone, text message, or email about your request, including by the independent professionals who may fulfill it.

Prefer to text? Text Now
Call Now - 24/7 Dispatch